Product Details:
| Minimum Order Quantity | 1 Piece |
| Patient Type | Adult & Pediatric |
| Ventilation Mode | Invasive & NIV |
| Application | ICU & Transport |
| Tidal Volume | 50ml |
| Display Size | 7 inch |
| Power Source | Electric & Battery |
| Breath Modes | VC; PC; SIMV, APRV |
| O2 Supply | Cylinder & Central, Inbuilt Turbine, Cylinder O2, Central O2 |
| Mobility | Trolley Mounted |
GE Versamed i Vent 201 Ventilator
GE Versamed Ventilator
IVent 201 Ventilator
Versamed Ventilator
ICU Ventilator
Adult and Paediatric Ventilator
Product Details:
| Patient Type | Adult & Pediatric |
| Ventilation Mode | Invasive & NIV |
| Weight | 5-8 kg |
| Battery Backup | <2 hr |
| Tidal Volume | 50-1500 ml |
| Mounting | Portable, Wall Mount, Ambulance Mount, Trolley Mount |
Product Details:
| Minimum Order Quantity | 1 Piece |
| Type | Critical Care Ventilators |
| Requirement Type | Refurbished |
| Ventilator With Trolley | Yes |
| Tidal Volume | 20 to 2000 mL |
| Patient Age Group | Adult, Paediatric |
| Volume Controlled Ventilation (Assist./Cont.): VCV Pressure Controlled Ventilation(Assist./Cont.): PCV Synchronized Intermittent Mandatory Ventilation: V-SIMV and P-SIMV Pressure Support Ventilation (Spont., CPAP): PSV Continuous Positive Airway Pressure: CPAP Volume Assured Pressure Support: VAPS Mandatory Rate Ventilation: MRV (Patented feature) Airway Pressure Release ventilation: APRV Pressure Regulated Volume Control: PRVC Intermittent Mandatory Pressure Release Ventilation: IMPRV Duo Levels: Bi-level pressure ventilation Ventilation modes - Non Invasive Ventilation PS-PEEP NIV: Non Invasive Spontaneous Ventilation with pressure support and PEEP, VCV-NIV, PCV-NIV, SIMV-NIV, PSV-NIV Monitoring Static compliance and resistance: Automatic measurement in VCV Total PEEP: Automatic measurement in VCV Plateau pressure: Automatic measure in VCV Curves: Flow (t), Pressure (t) Loops: P/V, V/F, F/P, FiO2 : 21 to 100% Trends: 72 hrs for 14 parameters. Monitoring of FiCO2 and EtCO2 Events log: (ventilation and alarms settings, alarms, suction, pauses): 10,000 events Built-in battery back up |
Tidal volume (VTi): 20 to 2000 mL Inspiratory peak flow: 0 to 200 L/min Maximum inspiratory peak flow: >200 L/min (depending on gas supply pressures) Respiratory rate (RR): 5 to 100 bpm SIMV respiratory rate (RR SIMV): 1 to 60 bpm Inspiratory plateau (Tplat): 0 to 60% of IT Inspiratory time (TI): Infants: 0.3 s to 60% of Ttot Positive end expi. pressure (PEEP): 0 to 40 cmH2O Pressure support (PS): 0 to 35 cmH2O Insufflation pressure (PI): 2 to 60 cmH2O Maximum insufflation pressure: 90 cmH2O Pressure slope (Slope): 50 to 150 cmH2O/s Flow wave shape: Constant, decelerating, sinusoidal FiO2: 21 to 100 % Inspiratory flow trigger (PEEP=0): 0.1 to 5L/min Expiratory trigger: 0 (OFF) to 70% of peak flow Inspiratory pause: 0 to 5 s Expiratory pause: 0 to 12 s Sustained exhalation: 0 to 30 s Sigh rate: OFF, 1/9 to 1/200 cycles Sigh in CMV and in PCV: 1 to 2 x VT Nebulization: 1.5 bar (150 kPa) |